In minimally invasive surgery, a clear operative field and stable pneumoperitoneum pressure are central to both safety and procedural efficiency. The Olympus UHI-3 high-flow insufflator pairs high-flow gas delivery with integrated smoke evacuation, offering surgical teams a consolidated approach to insufflation management built around precise pressure regulation and simplified controls.

Core technical capabilities

The UHI-3 functions as more than a gas supply unit; it is designed as a workflow component within the operating room. Its principal strengths lie in the combination of high-flow delivery and continuous pressure monitoring, allowing the system to respond rapidly to gas loss caused by instrument movement and to hold intra-abdominal pressure at the level selected by the surgical team.

Feature Specification
Maximum flow rate 35 L/min high-flow gas delivery
Flow modes Three adjustable settings: low, medium and high
Smoke evacuation Integrated smoke and mist evacuation
Gas connection Compatible with hospital central gas supply or gas cylinders
Safety mechanisms Automatic pressure relief valve with audible and visual alarms

Three selectable flow settings give the surgical team latitude to match delivery to the stage of the procedure, while the unit can draw on either a hospital central gas pipeline or conventional cylinders depending on room configuration.

Supporting operating room efficiency

With integrated smoke evacuation, the UHI-3 can clear surgical smoke and mist during a procedure when the optional footswitch is used. The arrangement is intended to keep the operative field consistently visible and to reduce the distraction that follows when visibility is obscured.

Connection to a hospital central gas supply also removes the routine burden of exchanging heavy cylinders during cases, allowing staff to concentrate on the procedure rather than on gas logistics.

Monitoring and safety design

Safety considerations are embedded in the unit's control interface. A front-panel display presents both the current pressure and the preset target simultaneously, so that critical readings remain visible at a glance.

If intra-abdominal pressure moves beyond the configured safety range, the system triggers audible and visual alarms and releases excess pressure through an automatic relief valve on the suction line, a design intended to limit risk during the case.

Frequently Asked Questions

Does the smoke evacuation function require additional equipment?
Yes. Smoke evacuation is operated in conjunction with an optional smoke evacuation footswitch. Depressing the pedal starts the evacuation cycle, helping to maintain a clear operative field.
Can the device be connected to more than one gas cylinder at a time?
The UHI-3 can be fitted with an optional three-way CO2 adapter that supports simultaneous connection to two cylinders, with switching permitted during a procedure to reduce interruptions caused by a depleted supply.
How does the system respond to gas leakage during surgery?
The unit's 35 L/min high-flow capacity allows it to react quickly to pressure changes within the abdominal cavity, automatically supplying additional gas to maintain the set pressure level.